Issue
Both ALI ports are down
- Critical Diagnostic from slave server ALI Group 1 Both ALI ports are down
Environment
- VESTA 9-1-1
- Legacy ALI
- i3 ALI
- Old Links cutover to NEW ALI
Resolution
Steps should be completed by the proper channel upon successful/tested new ALI configuration
Login: DDS Configurator > ALI Configuration > ALI Groups (locate the group that is no longer in use and note the sources)
Delete
Navigate to:
ALI Sources (use the drop-down to enter config of the unused port)
Delete
Are you Sure? Yes/Cancel > Yes to proceed
Navigate back to: ALI Groups
Delete Group (if any error, please make sure the sources are set to NONE)
Are you sure? Yes/Cancel > Yes to proceed
REMINDER:
Removing Sources and ALI Group will leave any previous lines configured with ALI Group associated will no longer work if brought back online.
Terms of Use Disclaimer - The information provided in this article is intended to help guide customers on how to address situations that they may encounter with their products. Care has been taken to ensure the accuracy of the information on this site. Motorola Solutions Inc. and its affiliates and subsidiaries, including but not limited to Motorola Solutions Connectivity, Inc., assume no responsibility or liability for any errors or omissions in the content of this article, or any data or configuration loss that may result by employing this information, which is provided “as is” and “as available”, with no guarantees of completeness, accuracy, usefulness or timeliness. By using this article, you agree to these terms and conditions.