APX NEXT XN with an invalid field Hazard Zone Mode Personality (HZM) will not clear invalid field after conditions are fulfilled.


Issue

When HZM is Enabled, the following conditions must be fulfilled:

The system selected for the current trunking personality is set to an ASTRO25 system and the Emergency Alarm Rx Indicator field is enabled in the selected system.

Trunking Emergency Profile Selection field is connected to a trunking emergency profile and is not set to Emergency Tx Disabled.

If the Emergency Revert Type field is set to System Revert, the Revert Channel must be set to match the HZM personality when HZM Personality field is checked.

 


Correcting the above conditions still shows Hazard Zone Mode Personality as an invalid field.

Environment

APX NEXT XN Programming in APX CPS

Resolution

Disable/Uncheck Hazard Zone Mode Personality, make the necessary changes to meet the required conditions then re-check the Hazard Zone Mode Personality Box