Error
APX mobile using O2 or O7 control head and programmed with Site Lock/Unlock menu does not label the UNLK and EXIT submenu buttons correctly
The Function button programmed for Site UNLK, menu button 2, is not labeled. The label has shifted to menu button 3. However, menu button 2 will still perform the site UNLK function. Menu button 3 will sound a bonk. The EXIT menu button, button 4, is not labeled either
Menu button 2 still provides the site unlock functionality, even though it is not labeled as such.
Environment
APX Mobile using O2 or O7 Control head
One of the Function buttons programmed for Site Lock
Firmware R20.00.00 – R21.01.30
Root Cause
Firmware defect
Workaround/Fix
Work Around :
Menu button 2 still provides the site unlock functionality, even though it is not labeled as such.
Fix :
Upgrade firmware to R21.23.00 or higher