APX Mobile using O2 or O7 CH with Site Lock menu displays incorrectly


Error

APX mobile using O2 or O7 control head and programmed with Site Lock/Unlock menu does not label the UNLK and EXIT submenu buttons correctly

The Function button programmed for Site UNLK, menu button 2, is not labeled. The label has shifted to menu button 3. However, menu button 2 will still perform the site UNLK function. Menu button 3 will sound a bonk. The EXIT menu button, button 4, is not labeled either

Menu button 2 still provides the site unlock functionality, even though it is not labeled as such.

Environment

APX Mobile using O2 or O7 Control head

One of the Function buttons programmed for Site Lock

Firmware R20.00.00 – R21.01.30

Root Cause

Firmware defect

Workaround/Fix

Work Around :

Menu button 2 still provides the site unlock functionality, even though it is not labeled as such.

Fix :

Upgrade firmware to R21.23.00 or higher