Codeplug comparator tool fails to compare two codeplugs when using R20 APX CPS


Error

Both are saved as R20 with the same baseline default codeplug

The same operation with R19 CPS has no issue
APX CPS Codeplug comparator tool fails to compare 2 codeplugs when using R20 CPS

Comparing two nearly identical Codeplugs works only in one direction – when one is opened first and then the other to compare, the comparator function works. When the codeplugs are opened in the reverse order for the same comparison, the comparison fails

Environment

 APX CPS

Root Cause

Software defect

Workaround/Fix

This is resolved in SR2020.2 (R21.40.00) of CPS/RM or newer.